In the complex world of industrial valves, selecting the right standard is critical for safety, performance, and compliance. Two of the most referenced specifications are ASME B16.34 and API 600. While they both govern steel valves, their scope and application differ significantly. This guide breaks down the key differences to help engineers and procurement specialists make informed decisions.

Core Purpose and Scope

ASME B16.34 is a foundational standard from the American Society of Mechanical Engineers. It provides the fundamental requirements for the design, fabrication, pressure-temperature ratings, and testing of valves made from forgings, castings, and plate materials. Its scope is broad, covering various valve types like gate, globe, check, and ball valves for a wide range of applications.

API 600, from the American Petroleum Institute, is a more specific specification. It details requirements for bolted bonnet steel gate valves primarily for the petroleum and natural gas industries. API 600 is essentially a “valve product standard” that builds upon the foundational rules of ASME B16.34 but adds stringent, industry-specific requirements for materials, design, and testing.

Key Differences in Design and Testing

The differences become clear in execution. API 600 mandates specific material grades, requires a minimum wall thickness often greater than B16.34’s minimums, and has strict rules for bolting, stem diameter, and sealing. For testing, both standards require shell and seat tests, but API 600 often dictates more rigorous or additional testing protocols suitable for hydrocarbon service.

Think of it this way: ASME B16.34 sets the baseline construction code for steel valves. API 600 takes that baseline and applies enhanced, prescriptive requirements to create a valve specifically engineered for the demanding conditions of oil and gas production, refining, and pipelines.

Choosing the Right Standard for Your Application

Your choice depends on the service. For general industrial services, power plants, or lower-pressure hydrocarbon services, valves manufactured to ASME B16.34 may be perfectly adequate and cost-effective. For critical, high-pressure, high-temperature, or sour service applications in upstream and downstream oil & gas, API 600 is typically specified by operators and mandated by project standards.

For a deeper technical dive into the specifications, you can explore this detailed resource on two commonly asme b16 34 and api 600.

Frequently Asked Questions (FAQ)

Can a valve be compliant with both ASME B16.34 and API 600?

Yes. In fact, API 600 states that valves conforming to its standard shall also meet the requirements of ASME B16.34. API 600 compliance inherently meets B16.34, but not vice-versa.

Which standard is more stringent?

API 600 is generally more stringent and prescriptive for gate valves in hydrocarbon service, particularly regarding materials, wall thickness, and design details.

Is API 600 only for gate valves?

Yes, API 600 specifically covers bolted bonnet steel gate valves. ASME B16.34 covers multiple valve types.